Yuav Ua Li Cas Xaiv Ib Qhov Zoo Tshaj Tawm Voltage Tester?

Kuv Lub Tebchaws tau dhau los ua lub hauv paus loj tshaj plaws hauv ntiaj teb rau cov khoom siv hauv tsev thiab cov khoom siv hluav taws xob thiab hluav taws xob, thiab nws cov khoom xa tawm tseem nce ntxiv.Ua ke nrog cov neeg siv khoom 'kev nyab xeeb khoom, nyob rau hauv txoj kab nrog cov kev cai thoob ntiaj teb thiab cov kev cai, cov neeg tsim khoom txuas ntxiv txhim kho cov qauv kev nyab xeeb ntawm cov khoom.Tsis tas li ntawd, Cov Chaw Tsim Khoom kuj tseem them nyiaj tshwj xeeb rau kev soj ntsuam kev nyab xeeb ntawm cov khoom ua ntej tawm hauv lub Hoobkas.Nyob rau lub sijhawm no, kev nyab xeeb ntawm cov khoom siv hluav taws xob ntawm cov khoom, tej zaum muaj kev nyab xeeb tiv thaiv hluav taws xob, yog ib qho tseem ceeb heev rau cov khoom kuaj nyob rau lub sijhawm no.
 
Txhawm rau kom nkag siab txog cov khoom siv hluav taws xob rwb thaiv tsev, cov khoom lag luam npaj, cov qauv, thiab cov khoom siv rwb thaiv tsev muaj cov kev qhia tshwj xeeb lossis cov kev qhia tshwj xeeb.Feem ntau, cov neeg tsim khoom yuav siv ntau txoj hauv kev los kuaj lossis kuaj.Txawm li cas los xij, rau cov khoom siv hluav taws xob, muaj ib hom kev sim uas yuav tsum tau ua, uas yog-Dielectric Withstand Test, qee zaum hu ua Hipot Test lossis Hipot Test, High Voltage Test, Hluav Taws Xob Test, thiab lwm yam Cov Kev Ntsuas Hluav Taws Xob ntawm General Cov khoom zoo los yog phem;Nws tuaj yeem cuam tshuam los ntawm Kev Ntsuas Hluav Taws Xob.
  
Muaj ntau ntau hom kev tiv thaiv hluav taws xob hauv khw tam sim no.Raws li cov neeg tsim khoom muaj kev txhawj xeeb, yuav ua li cas kom txuag tau peev peev thiab lawv tus kheej xav tau kev yuav khoom siv nrog cov ntsuas hluav taws xob tau dhau los ua qhov tseem ceeb dua.
 
1. Hom Kev Ntsuas Hluav Taws Xob (Kev Sib Txuas Lus lossis DC)
 
Cov kab ntau lawm tiv thaiv qhov ntsuas hluav taws xob, qhov kev xeem dhau los (Routine Test), Raws li cov khoom sib txawv, muaj kev sib txuas lus tiv thaiv qhov ntsuas hluav taws xob thiab DC tiv thaiv qhov ntsuas hluav taws xob.Pom tseeb, Kev Sib Txuas Lus Nrog Kev Ntsuas Hluav Taws Xob yuav tsum xav txog seb qhov zaus ntawm qhov ntsuas qhov ntsuas hluav taws xob zoo li cas nrog kev ua haujlwm zaus ntawm cov khoom kuaj;Yog li ntawd, Qhov Muaj Peev Xwm Txaus Siab Xaiv Hom Kev Ntsuas Hluav Taws Xob thiab Kev Xaiv Yooj Yim Ntawm Kev Sib Txuas Lus Sib Txuas Lus yog Cov Haujlwm Tseem Ceeb Ntawm Cov Hluav Taws Xob Hluav Taws Xob..
 
2. Kev ntsuas qhov ntsuas hluav taws xob
 
Feem ntau, qhov tso zis ntsuas ntawm qhov ntsuas hluav taws xob ntawm kev sib txuas lus nrog hluav taws xob ntsuas ntsuas yog 3KV, 5KV, 10KV, 20KV, Thiab txawm tias siab dua, thiab qhov tso zis hluav taws xob ntawm DC tiv thaiv qhov ntsuas hluav taws xob yog 5KV, 6KV lossis txawm siab dua 12KV.Tus neeg siv yuav xaiv qhov tsim nyog qhov ntsuas hluav taws xob li cas rau nws daim ntawv thov?Raws li cov khoom sib txawv, qhov ntsuas hluav taws xob ntawm cov khoom muaj cov cai tswj kev nyab xeeb.Piv txwv li, Hauv IEC60335-1: 2001 (GB4706.1), Qhov Kev Ntsuas Hluav Taws Xob ntawm Kev Ua Haujlwm Kub Kub muaj qhov ntsuas tus nqi rau qhov ntsuas hluav taws xob.Hauv IEC60950-1: 2001 (GB4943), Kev Ntsuas Hluav Taws Xob Ntawm Cov Hluav Taws Xob Hluav Taws Xob kuj tau taw qhia.
 
Raws li Cov Khoom Siv thiab Cov Kev Qhia Kom Zoo, Kev Ntsuas Hluav Taws Xob kuj txawv.Hais txog Lub Tuam Txhab Tuam Txhab Kev Xaiv 5KV Thiab DC 6KV Nrog Kev Ntsuas Hluav Taws Xob, Nws tuaj yeem ua tau raws li qhov xav tau, tab sis hais txog qee lub koom haum kuaj tshwj xeeb lossis cov neeg tsim khoom txhawm rau txhawm rau teb cov khoom sib txawv, nws yuav tsum xaiv cov khoom siv 10KV thiab 20KV. Kev sib txuas lus lossis DC.Yog li ntawd, Muaj peev xwm tswj tau qhov tso zis hluav taws xob kuj tseem yog qhov yuav tsum tau muaj ntawm Kev Tiv Thaiv Voltage Tester.
 
3. Lub Sijhawm Quiz
 
Raws li cov khoom Specifications, General Withstand Voltage Test yuav tsum tau 60 vib nas this thaum lub sij hawm.Qhov no yuav tsum tau ua nruj me ntsis hauv cov koom haum soj ntsuam kev nyab xeeb thiab cov chaw ua haujlwm hauv Hoobkas.Txawm li cas los xij, Qhov Kev Ntsuas Zoo li no yuav luag tsis muaj peev xwm ua tau raws li cov kab ntau lawm thaum lub sijhawm.Lub hom phiaj tseem ceeb yog nyob rau kev ceev ceev thiab kev ua haujlwm ntawm kev tsim khoom, yog li kev sim mus sij hawm ntev tsis tuaj yeem txaus siab rau cov kev xav tau.Hmoov zoo, Ntau lub koom haum tam sim no tso cai xaiv kom luv lub sij hawm xeem thiab nce qhov ntsuas hluav taws xob.Tsis tas li ntawd, Qee Txoj Cai Kev Nyab Xeeb Tshiab kuj tseem qhia meej txog lub sijhawm xeem.Piv txwv li, Hauv Cov Lus Qhia Ntxiv A Ntawm IEC60335-1, IEC60950-1 Thiab Lwm Cov Kev Qhia Tshwj Xeeb, Nws tau hais tias Kev Xeem Routine (Routine Test) Lub Sijhawm yog 1sec.Yog li ntawd, qhov teeb tsa ntawm Lub Sij Hawm Kev Ntsuas kuj tseem yog ib qho tseem ceeb ntawm Kev Tiv Thaiv Voltage Tester.
 
Plaub, Qhov Voltage Slow Rise Function
 
Ntau yam kev tswj hwm kev nyab xeeb, xws li IEC60950-1, piav qhia cov yam ntxwv tso zis ntawm qhov ntsuas hluav taws xob raws li hauv qab no: "Kev ntsuas hluav taws xob siv rau lub rwb thaiv tsev hauv kev ntsuas yuav tsum maj mam nce ntawm xoom mus rau qhov ntsuas hluav taws xob tsis tu ncua ...";IEC60335-1 Cov lus piav qhia hauv: "Thaum pib ntawm qhov kev sim, qhov kev siv hluav taws xob tsis dhau ib nrab ntawm tus nqi hluav taws xob tsis tu ncua, thiab tom qab ntawd maj mam nce mus rau tag nrho tus nqi."Lwm Txoj Cai Kev Nyab Xeeb kuj tseem muaj cov kev xav tau zoo sib xws, uas yog, qhov hluav taws xob tsis tuaj yeem siv tam sim ntawd rau cov khoom ntsuas, thiab yuav tsum muaj cov txheej txheem qeeb qeeb.Txawm hais tias Cov Lus Qhia Tshwj Xeeb Tsis Muaj Cov Lus Qhia Kom Paub Txog Lub Sijhawm Ntxiv rau qhov kev nthuav dav qeeb qeeb, nws lub hom phiaj yog txhawm rau tiv thaiv kev hloov pauv sai.High Voltage yuav ua rau lub rwb thaiv tsev muaj nuj nqi ntawm cov khoom ntsuas.
 
Peb paub tias qhov ntsuas qhov ntsuas hluav taws xob yuav tsum tsis yog qhov kev sim ua kom puas tsuaj, tab sis yog ib qho kev kuaj xyuas cov khoom tsis raug.Yog li ntawd, Tus Txhaum Voltage Tester yuav tsum muaj qhov ua haujlwm qeeb qeeb.Tau kawg, yog tias pom muaj qhov txawv txav thaum lub sij hawm nce qeeb, cov cuab yeej yuav tsum tuaj yeem nres tam sim ntawd, yog li ntawd qhov kev sib xyaw ua ke ua rau lub luag haujlwm vivid.
 
 
 
Tsib, Kev Xaiv Kev Xeem Tam Sim No
 
Los ntawm cov kev xav tau saum toj no, peb tuaj yeem pom tias, qhov tseeb, qhov yuav tsum tau muaj ntawm Cov Kev Cai Tswj Xyuas Kev Nyab Xeeb Txog Kev Tiv Thaiv Voltage Tester yeej muab cov kev xav tau meej dua.Txawm li cas los xij, Lwm qhov kev txiav txim siab hauv kev xaiv qhov ntsuas qhov ntsuas hluav taws xob yog qhov ntsuas ntawm qhov ntsuas tam sim no.Ua ntej qhov kev sim, Nws yog qhov tsim nyog los teeb tsa qhov kev sim ntsuas hluav taws xob, lub sijhawm sim thiab txiav txim siab tam sim no (Lub Sij Hawm Tshaj Lij Tshaj Lij Tshaj Tawm tam sim no).Cov tam sim no tiv taus qhov ntsuas hluav taws xob ntawm Kev Ua Lag Luam Siv Kev Sib Txuas Tam Sim No Ua piv txwv.Qhov siab tshaj plaws qhov hluav taws xob tam sim no uas ntsuas tau yog kwv yees li ntawm 3mA txog 100mA.Tau kawg, qhov siab dua qhov ntsuas qhov ntsuas qhov ntsuas tam sim no, qhov siab dua tus txheeb ze.Tau kawg, Ntawm no peb ib ntus xav txog qhov ntsuas qhov tseeb tam sim no thiab kev daws teeb meem ntawm tib theem!Yog li, Yuav Ua Li Cas Xaiv Ib Lub Cuab Yeej Zoo Rau Koj?Ntawm no, Peb kuj tseem nrhiav qee cov lus teb los ntawm Cov Lus Qhia.
 
Los ntawm cov lus qhia hauv qab no, peb tuaj yeem pom yuav ua li cas Qhov Kev Ntsuas Hluav Taws Xob tau txiav txim siab hauv cov lus qhia:
Specification Title Cov lus qhia hauv Specification los txiav txim qhov tshwm sim ntawm kev tawg
IEC 60065: 2001 (GB 8898)
"Kev Nyab Xeeb Kev Ruaj Ntseg Rau Lub Suab, Yees Duab Thiab Cov Khoom Siv Hluav Taws Xob Zoo sib xws" 10.3.2…… Thaum Lub Sijhawm Kev Ntsuas Hluav Taws Xob, Yog tias Tsis Muaj Teeb Meem lossis tawg, Cov khoom siv tau pom tias ua tau raws li qhov yuav tsum tau ua.
IEC 60335-1: 2001 (GB4706.1)
"Kev nyab xeeb ntawm tsev neeg thiab cov khoom siv hluav taws xob zoo sib xws Tshooj 1: Cov Lus Qhia dav dav" 13.3 Thaum lub sij hawm sim, yuav tsum tsis txhob tawg.
IEC 60950-1: 2001 (GB4943)
"Kev nyab xeeb ntawm cov khoom siv thev naus laus zis" 5.2.1 Thaum Lub Sijhawm Kev Ua Haujlwm, Lub rwb thaiv tsev yuav tsum tsis txhob tawg.
IEC 60598-1: 1999 (GB7000.1)
"Cov Lus Qhia Txog Kev Nyab Xeeb Kev Nyab Xeeb thiab Kev sim rau cov teeb thiab teeb" 10.2.2… Thaum lub sij hawm sim, tsis muaj flashover lossis tawg yuav tshwm sim.
Table I
 
Nws tuaj yeem pom los ntawm Table 1 tias qhov tseeb, hauv cov lus qhia tshwj xeeb no, tsis muaj cov ntaub ntawv meej meej los txiav txim seb qhov rwb thaiv tsev tsis raug.Hauv lwm lo lus, Nws tsis qhia koj pes tsawg cov khoom tam sim no tsim nyog lossis tsis tsim nyog.Ntawm chav kawm, muaj cov cai cuam tshuam txog qhov kev txwv siab tshaj plaws ntawm kev txiav txim siab tam sim no thiab lub peev xwm yuav tsum tau muaj ntawm qhov ntsuas qhov ntsuas hluav taws xob hauv qhov tshwj xeeb;Qhov kev txwv siab tshaj plaws ntawm qhov kev txiav txim siab tam sim no yog ua kom muaj kev tiv thaiv overload (In the Withstand Voltage Tester) Act los qhia txog qhov tshwm sim ntawm kev tawg tam sim no, kuj tseem hu ua Kev Tawm Tsam Tam Sim No.Cov lus piav qhia ntawm qhov txwv no nyob rau hauv ntau qhov tshwj xeeb yog qhia hauv Table 2.
 
Specification Title Maximum Rated Current (Trip Current) Short-Circuit Current
IEC 60065: 2001 (GB 8898)
"Cov Lus Qhia Txog Kev Nyab Xeeb Rau Cov Suab, Yees Duab thiab Cov Khoom Siv Hluav Taws Xob" 10.3.2…… Thaum cov zis tam sim no tsawg dua 100mA, Cov Khoom Siv Hluav Taws Xob yuav tsum tsis txhob cuam tshuam.Qhov ntsuas hluav taws xob yuav tsum tau muab los ntawm Kev Siv Hluav Taws Xob.Kev Siv Hluav Taws Xob yuav tsum tau npaj kom paub tseeb tias thaum qhov ntsuas hluav taws xob tau hloov kho mus rau qib sib xws thiab cov khoom siv hluav taws xob tau luv luv, cov zis tam sim no yuav tsum yog tsawg kawg 200mA.
IEC 60335-1: 2001 (GB4706.1)
"Kev nyab xeeb ntawm tsev neeg thiab cov khoom siv hluav taws xob zoo sib xws Tshooj 1: Cov Lus Qhia dav dav" 13.3: Kev mus ncig tam sim no Ir Short-Circuit Current Is
<4000 Ir = 100mA 200mA
≧4000 Thiab <10000 Ir = 40mA 80mA
≧10000 Thiab ≦20000 Ir = 20mA 40mA
IEC 60950-1: 2001 (GB4943)
"Kev Nyab Xeeb Ntawm Cov Khoom Siv Technology" Tsis tau hais meej meej tsis tau hais meej meej
IEC 60598-1: 1999 (GB7000.1-2002)
"Cov Lus Qhia Txog Kev Nyab Xeeb Kev Nyab Xeeb thiab Kev sim ntawm cov teeb thiab teeb" 10.2.2…… Thaum cov zis tam sim no tsawg dua 100mA, Lub Overcurrent Relay yuav tsum tsis txhob txiav.Rau qhov High Voltage Transformer siv nyob rau hauv qhov kev sim, thaum qhov tso zis voltage yog hloov mus rau qhov sib thooj kev sim voltage thiab cov zis yog luv luv-Circuited, cov zis tam sim no tsawg kawg yog 200mA
Table II
 
Yuav ua li cas los teeb tsa tus nqi kom raug ntawm cov dej ntws tam sim no
 
Los ntawm Cov Cai Tswj Kev Nyab Xeeb saum toj no, ntau tus neeg tsim khoom yuav muaj lus nug.Yuav Ua Li Cas Thiaj Li Yuav Tsum Tau Txais Tam Sim No Hauv Kev Xyaum Xaiv?Nyob rau theem thaum ntxov, peb tau hais meej meej tias Lub Peev Xwm Ntawm Cov Hluav Taws Xob Hluav Taws Xob yuav tsum yog 500VA.Yog tias qhov ntsuas hluav taws xob yog 5KV, tom qab ntawd cov dej ntws tam sim no yuav tsum yog 100mA.Tam sim no nws zoo li qhov yuav tsum tau muaj peev xwm ntawm 800VA rau 1000VA tseem xav tau.Tab sis Puas yog Tus Tuam Txhab Daim Ntawv Thov Kev Pabcuam Muaj Qhov Xav Tau no?Txij li thaum peb paub tias qhov loj dua qhov muaj peev xwm, tus nqi siab dua ntawm cov cuab yeej siv tau nqis peev, thiab nws kuj tseem ceeb heev rau tus neeg ua haujlwm.Kev xaiv ntawm cov cuab yeej yuav tsum xav txog tag nrho cov kev sib raug zoo ntawm cov kev xav tau tshwj xeeb thiab cov cuab yeej siv ntau yam.
 
Nyob rau hauv qhov tseeb, thaum lub sij hawm ntau lawm kab xeem txheej txheem ntawm ntau manufacturers, lub Upper Limit ntawm cov leakage tam sim no feem ntau siv ob peb yam kev txiav txim tam sim no tus nqi: xws li 5mA, 8mA, 10mA, 20mA, 30mA rau 100mA.Ntxiv mus, Kev paub qhia peb tias qhov ntsuas qhov tseeb thiab qhov yuav tsum tau muaj ntawm cov kev txwv no yeej nyob deb ntawm ib leeg.Txawm li cas los xij, Nws raug pom zoo tias thaum xaiv qhov tsim nyog nrog qhov ntsuas hluav taws xob, nws yog qhov zoo dua los xyuas nrog cov lus qhia ntawm cov khoom.
 
Yog xaiv Cov khoom siv ntsuas hluav taws xob tsis raug
Feem ntau, Thaum Xaiv Ib Qhov Kev Ntsuas Hluav Taws Xob, Tej zaum yuav muaj qhov yuam kev hauv kev paub thiab nkag siab txog cov cai tswj kev nyab xeeb.Raws li Txoj Cai Kev Nyab Xeeb Kev Nyab Xeeb, Kev Tawm Tsam Tam Sim No yog 100mA, thiab luv luv-Circuit Tam sim no xav tau kom ncav cuag 200mA.Yog hais tias nws tau piav qhia ncaj qha raws li lub npe hu ua 200mA Withstand Voltage Tester yog qhov txhaum loj.Raws li peb paub, Thaum cov zis tawm qhov hluav taws xob yog 5KV;Yog tias qhov tso zis tam sim no yog 100mA, Qhov ntsuas qhov ntsuas hluav taws xob muaj peev xwm ntawm 500VA (5KV X 100mA).Thaum cov zis tam sim no yog 200mA, nws yuav tsum tau muab ob npaug rau qhov tso zis muaj peev xwm rau 1000VA.Qhov kev piav qhia yuam kev zoo li no yuav ua rau muaj nuj nqis rau kev yuav khoom.Yog tias Cov Nyiaj Txiag Muaj Tsawg;Keeb Kwm Muaj peev xwm yuav tau ob lub cuab yeej, vim yog qhov yuam kev ntawm kev piav qhia, tsuas yog ib qho tuaj yeem yuav.Yog li ntawd, Los ntawm Cov Lus Qhia saum toj no, Nws tuaj yeem pom tau tias Lub Chaw Tsim Khoom Xaiv Tau Txais Kev Ntsuas Hluav Taws Xob.Seb yuav xaiv ib tug loj-muaj peev xwm thiab dav-Range ntsuas nyob ntawm seb tus yam ntxwv ntawm cov khoom thiab cov yuav tsum tau ntawm cov specification.Yog tias koj xaiv cov cuab yeej dav dav thiab cov cuab yeej siv, nws yuav yog qhov pov tseg loj heev, lub hauv paus ntsiab lus yog tias nws txaus, nws yog qhov kev lag luam tshaj plaws.
 
Nyob rau hauv xaus
 
Ntawm chav kawm, vim yog qhov nyuaj ntawm cov kab kev sim ntsuas, cov txiaj ntsig kev xeem tau cuam tshuam loj heev los ntawm cov xwm txheej xws li Man-made thiab Environmental Factors, uas yuav cuam tshuam ncaj qha rau cov txiaj ntsig kev xeem, thiab cov xwm txheej no muaj kev cuam tshuam ncaj qha rau tus nqi tsis zoo. Khoom.Xaiv Qhov Zoo Tshaj Tawm Voltage Tester, tuav cov ntsiab lus tseem ceeb saum toj no, thiab ntseeg tias koj yuav muaj peev xwm xaiv qhov ntsuas qhov ntsuas hluav taws xob tsim nyog rau koj lub tuam txhab cov khoom.Raws li Yuav Ua Li Cas Tiv Thaiv Thiab Txo Cov Kev Txiav Txim Siab, Nws kuj yog ib feem tseem ceeb ntawm Kev Ntsuas Siab.

Post lub sij hawm: Feb-06-2021
  • facebook
  • linkedin
  • youtube
  • twitter
  • blogger
Cov khoom tshwj xeeb, Daim ntawv qhia chaw, Digital High Voltage Meter, High Voltage Meter, Voltage Meter, High-Voltage Digital Meter, High Voltage Calibration Meter, High Static Voltage Meter, Tag nrho cov khoom

Xa koj cov lus rau peb:

Sau koj cov lus ntawm no thiab xa tuaj rau peb